Everything about Instruction Set Simulator totally explained
An
Instruction Set Simulator (ISS) is a
simulation model, usually, but by no means always, coded in a high-level language, which mimics the behavior of a mainframe or
microprocessor by "reading"instructions and maintaining internal variables which represent the processor's
registers.
Instruction simulation is a methodology employed for one of several possible reasons:
- To simulate the machine code of another hardware device or entire computer for upward compatibility -- a full system simulator typically includes an instruction set simulator.
- To monitor and execute the machine code instructions (but treated as an input stream) on the same hardware for test and debugging purposes, for example with memory protection (which protects against accidental or deliberate Buffer overflow).
- To improve the speed performance of simulations involving a processor core where the processor itself isn't one of the elements being verified; verilog simulation with ISS by means of PLI speeds considerably.
Implementation
An ISS is often provided with a
debugger in order for a software engineer to debug the program prior to obtaining target hardware.
GDB is one of debuggers which have compiled-in ISS. It is sometimes integrated with simulated peripheral circuits such as
timers,
interrupts,
serial port, general
I/O port, etc to mimic the behavior of
microcontroller.
The basic instruction simulation technique is the same regardless of purpose - first execute the monitoring program passing the name of the target program as an additional input parameter.
The target program is then loaded into memory, but control is never passed to the code. Instead, the entry point within the loaded program is calculated and a pseudo
Program status word (
PSW) is set to this location. A set of pseudo registers are set to what they'd have contained if the program had been given control directly.
(It may be necessary to amend some of these to point to other pseudo "control blocks" depending on the hardware and operating system. It may also be necessary to reset the original parameter list to 'strip out' the previously added program name parameter).
Thereafter, execution proceeds as follows:
1. Determine length of instruction at pseudo PSW location (initially the first instruction in the target program). If this instruction offset within program matches a set of previously given "pause" points, set "Pause" reason, go to 7.
2. "Fetch" the instruction from its original location (if necessary) into the monitor's memory. If "trace" is available and "on", store program name, instruction offset and any other values.
3. Depending upon instruction type, perform pre-execution checks and execute. If the instruction can't proceed for any reason (invalid instruction, incorrect mode etc) go to 7. If the instruction is about to alter memory, check memory destination exists (for this
thread) and is sufficiently large. If OK, load appropriate pseudo registers into temporary real registers, perform equivalent move with the real registers, save address and length of altered storage if trace is "on" and go to 4. If the instruction is a "register-to-register" operation, load pseudo registers into monitors real registers, perform operation, store back to respective pseudo registers, go to 4. If the instruction is a conditional branch, determine if the condition is satisfied: if not go to 4, if condition IS satisfied, calculate branch to address, determine if valid (if not, set error = "
Wild branch") and go to 7. If OK, go to 5. If instruction is an operating system call, do real call from monitorng program by "faking" addresses to return control to monitor program and then reset pseudo registers to reflect call; go to 4.
4. Add instruction length to current Pseudo PSW value.
5. Store next address in Pseudo PSW.
6. Go to 1.
7. Halt execution.
For test and debugging purposes, the monitoring program can provide facilities to view and alter registers, memory, and re-start location or obtain a mini
core dump or print symbolic program names with current data values. It could permit new conditional "pause" locations, remove unwanted pauses and suchlike.
Instruction simulation provides the opportunity to detect errors BEFORE execution which means that the conditions are still exactly as they were and not destroyed by the error. A very good example from the
IBM S/360 world is the following instruction sequence that can cause difficulties debugging without an instruction simulation monitor.
LM R1,R15,12(R13) where r13 incorrectly points to string of X"00"s
BR R14 causes PSW to contain X"0000002" with program check "Operation Exception"
* all registers on error contain nulls.
Consequences
Overhead
The number of instructions to perform the above basic "loop" (Fetch/Execute/calculate new address) depends on hardware but it could be accomplished on
IBM S/360/370/390/ES9000 range of machines in around 12 or 13 instructions for many instruction types. Checking for valid memory locations or for conditional "pause"s add considerably to the overhead but optimization techniques can reduce this to acceptable levels. For testing purposes this is normally quite acceptable as powerful debugging capabilities are provided including
instruction step, trace and deliberate jump to test error routine (when no actual error). In addition, a full instruction trace can be used to test actual (executed) code coverage.
Added benefits
Occasionally, monitoring the execution of a target program can help to highlight
random errors that appear (or sometimes disappear) while monitoring but not in real execution. This can happen when the target program is loaded at a different location than normal because of the physical presence of the monitoring program in the same address space.
If the target program picks up the value from a "random" location in memory (one it doesn't 'own' usually), it may for example be nulls (X"00") in almost every normal situation and the program works OK. If the monitoring program shifts the load point, it may pick up say X"FF" and the logic would cause different results during a comparison operation. Alternatively, if the monitoring program is now occupying the space where the value is being "picked up" from, similar results might occur.
Re-entrancy bugs: accidental use of
static variables instead of "dynamic" thread memory can cause re-entrancy problems in many situations. Use of a monitoring program can detect these even without a
storage protect key.
Illegal operations: some operating systems (or hardware) require the application program to be in the correct "mode" for certain calls to the Operating system. Instruction simulation can detect these conditions before execution.
Example
Typical trace output from simulation by monitoring program used for test & debugging:
Program offset instruction Dis-assembled register/ storage (after execution)
TEST001 000000 X'05C0' BALR R12,0 R12=002CE00A
000002 X'47F0C00E' BC 15,X'00E'(R12)
00000E X'98ECD00C' STM R14,R12,X'00C'(R13) X'002E0008' ==> X'00004CE,002CE008,..etc....'
000012 X'45E0C122' BAL R14,X'122'(R12) R14=002C0016
SUB1 000124 X'50E0C28A' ST R14,X'28A'(R12) X'002CE294' ==> X'002C0016'
etc...
Further Information
Get more info on 'Instruction Set Simulator'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://instruction_set_simulator.totallyexplained.com">Instruction Set Simulator Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |